1. ) Electric Resistance Heat-Strip Inspection 2. ) Voltage 3. ) Amp Draw Per Heat-Strip 4. ) Cheek All Electrical Wiring 5. ) Check & Inspect All Electrical Controls 6. ) Test Safeties 7. ) Temperature Rise Indoor Fan Motor Amperage 8. ) BTU 8c CFM Cakulaoons 9. ) Cheek Fan Rotation 8c Alignment 10. ) Oil Motor If Necessary 11. ) Vacuum Blower Compartment IX) Change Indoor Air Fiber (Customer Supplied) 13. ) Clean indoor Evaporate Coil 14. ) Clean Drain line 15. ) Inspect and/or Clean Air Cleaner 16. ) Inspect and/or Clean Humidifier, Change Pad

Gas Propane

1. ) Clean 8c Adjust Main Burners 8c Pilot Assembly 2. ) Cheek Flame Sensor Or Pilot Safety Output 3. ) Brush 8c Vacuum Heat Exchanger Compartments 4. ) Check Gas Pressure 5. ) Test AH Safeties 6. ) Throughly Inspect Health Exchanges 7. ) Cheek For Proper Sequence Of Operation 8. ) Check Temperature Splits 9. ) Inspect All Electrical Components 8t Wiring 10. ) Cheek For Carbon Monoxide In Flue 8c In Home 11. ) Complete Combustion Efficiency Test,

Print 8c Leave A Copy For The Homeowner 12. ) Vacuum Blower Compartment 13. ) Oil Blower Motor 14. ) Change Beh, Test 8c Adjust Tension

60.4%